Nozzle Velocities and Dimensions: |
|
|
|
|
|
|
Small Nozzle |
4 to 100 mph |
6 to 160 km/hr |
|
|
|
8.2 ft wide x 6.9 ft high |
2.5 m wide x 2.1 m high |
|
|
Large Nozzle |
4 to 45 mph |
6 to 70 km/hr |
|
|
|
9.8 ft wide x 11.4 ft high |
3.0 m wide x 3.5 m high |
|
Tunnel Dimensions: |
|
|
|
|
|
|
Maximum Distance from Roll to Small Nozzle |
19.3 ft |
5.9 m |
|
|
Maximum Distance from Roll to Large Nozzle |
33.5 ft |
10.2 m |
|
|
Test Section Length |
45.5 ft |
13.9 m |
|
|
Entrance Height |
12.1 ft |
3.69 m |
|
Climatic Simulation: |
|
|
|
|
|
|
Temperature Range |
-40 to 120 °F |
-40 to 50 °C |
|
|
Rate of Temperature Change (average) |
10 °F/hr |
5.5 °C/hr |
|
|
Humidity Range |
up to 95 %RH |
up to 95 %RH |
|
|
Solar Simulation |
320 BTU/hr ft² max. intensity |
1.0 kW/m² max. intensity |
|
|
|
over a 160 ft² surface |
over a 15 m² surface |
|
Chassis Roll Dynamometer: |
Rolls move horizontally and vertically to accommodate
front |
|
|
|
or rear wheel drive and tandem axle trucks |
|
|
Maximum Power |
400 hp @ 30 mph |
298 kW @ 48 km/hr |
|
|
Maximum Speed |
100 mph |
160 km/hr |
|
|
Maximum Tractive Force |
5000 lb |
2270 kg |
|
|
Maximum Axle Load |
20000 lb |
9080 kg |
|
Water Brake Dynamometer: |
Mounts between truck frame rails and couples to
driveshaft |
|
|
Maximum Power |
1000 hp |
746 kW |
|
|
|
|
|
|
|
General |
• Scan Rate: 20 scans / min |
|
|
• Log Rate: 2 samples / min (typical), 20 samples / min
(maximum) |
|
|
• Windows-based software for planning tests, for
controlling and monitoring the tunnel and |
|
|
vehicle, and for reporting results |
|
|
• Easy switching between English and metric units on
screen and in files/printouts |
|
|
• Up to 30 calculated "channels", updated every scan and
logged with data |
|
|
• Results provided as hardcopy, and/or in Microsoft
Excel or Lotus 1-2-3 formats, |
|
|
on CD or via e-mail |
|
|
|
|
Temperature |
• Up to 140 thermocouple channels, chosen from
selections below in banks of 16 |
|
|
• Up to 140 Type K |
• Up to 80 Type T |
• Up to 64 Type J |
|
|
|
• Grounded or ungrounded junctions |
|
|
|
Pressure |
• Transducers for measurement of gage, differential, and
vacuum |
|
|
• Twelve ranges from 1 to 5000 psi
(7 to 34467 kPa) |
|
|
• Up to 28 pressures measured simultaneously |
|
Flow |
• Turbine flowmeters for measuring flow of coolant,
refrigerant and transmission fluid, etc. in |
|
|
lines from 3/8” to 2” (10 to 51 mm) diameter and flow
ranges from 3 to 150 gpm (11.4 to 568 l/min) |
|
|
• Up to 4 flows measured simultaneously |
|
RPM |
• 4 channels of rpm measurement (infrared reflective
fiberoptic) for fan(s), engine, driveshaft, etc. |
|
Voltage and Current |
• 8 isolated channels, individually configurable to
measure DC voltage (to 50 V) or current (to 50 A), |
|
|
for fans, blowers, etc. DC power supplies for vehicle
systems up to 60 V |
|
Fuel Flow |
• Diesel fuel supply system incorporates mass flow
measurement to 200 lb/hr (91 kg/hr) |
|
|
to permit verification of engine operating
conditions. |